Total Failures

14024results

Total Downtime

75445.0h

Avg. Downtime

5.38h

High Risk

109results

AI Analysis

Incident Count

Monthly Downtime

Line Downtime (Top 10)

Equipment Name Downtime (Top 10)

Failure Location Breakdown

Failure Phenomenon Breakdown

Downtime Distribution

Top 10 Parts by Frequency

Maintenance Reports

Date ↓LineEquipment NameFailure LocationDescriptionHoursRisk
2026-08-30Die CastDie Cast 10Die Cast 10WHAT: robot fault at trim press why: chuck up down guide bolts loose an 1 snaped off c/m: took chuck off up/down cylinder an replaced all bolts for guide/ retaught sit down in trim press/retaught to knock off overflow0.0Medium
2026-08-30Die CastDie Cast 9Die Cast 9WHAT? Trim press scrap conveyor jammed WHY? Aluminum stuck inside CM? Reverse 2 leads on middle contactor, run backwards0.0Medium
2026-08-30Die CastDie Cast 7Die Cast 7WHAT: moving side water staying on why: solenoid valve bad c/m; took apart cleaned but worn very bad an still leaking after clean 0 parts in inventory kevin emailed burt0.0Medium
2026-08-29Die CastDie Cast 7Die Cast 7What: Channel 2 on the SQM not working Why: Bad Solenoid valve C/M: Replaced valve0.0Medium
2026-08-28Die CastDie Cast 10Die Cast 10WHAT? Unload Robot Faulted WHY? Part got jammed into trim press CM HOME robot, menu, system, variables, OPWORK, uot disable, 0 to 1 to clear fault.0.0Medium
2026-08-28Die CastDie Cast 2Die Cast 2What: DCM alarmed for Vacuum Equipment not on0.0Medium
2026-08-28Die CastDie Cast 3Die Cast 3WHAT? Air leak on robot WHY Broken air line CM Replace airline0.0Medium
2026-08-26Die CastDie Cast 1Die Cast 1What: Melting burner stuck at low fire. Why: EV! on Ex gas temp controller set to -928 instead of -10. C/M: Set EV1 to -100.0Medium
2026-08-26Die CastDie Cast 4Die Cast 4What: Half pipe cracked Why: Not a good style cracked and broke C/M: Replaced halfpipe0.0Medium
2026-08-26Die CastDie Cast 1Die Cast 1Cavity 2 and 3 slide cores are broke. replaced slide cores 2 and 3.0.0Medium
2026-08-25Die CastDie Cast 10Die Cast 10WHAT? Mel-keeper panel +24V power shorted out WHY? Tower sensor emitter melted because sight glass fell off. CM Swapped in both parts of sensor from 110.0Medium
2026-08-24Die CastDie Cast 3Die Cast 3What: Electrode malfunction Why: One of the wires to the probe broke. C/M: Replaced ladle wire and worked ladle back and fourth to confirm working with no electrode faults.0.0Medium
2026-08-21Die CastDie Cast 8Die Cast 8What: Trim Pres smashing parts Why: Robot not sitting in press correctly C/M: Retaught take out due to limit at press not allowing robot to be taught cause of hitting press0.0Medium
2026-08-21Die CastDie Cast 10Die Cast 10Melting furnace melting too fast/temperature too high Cause: gas flow too high Countermeasure: adjust gas flow down. 16.5 m/h down to 15.2 m/h ( match dc9)0.0Medium
2026-08-21Die CastDie Cast 5Die Cast 5What: Constant low aluminum. Why: Believe thermo coupler was bad. Said it was at temp but wasnt melting completly or fast enough. C/M: Replaced thermo coupler, confirmed melting got to temp but operator shut down.0.0Medium
2026-08-21Die CastDie Cast 2Die Cast 2What- Fixed side die temp issues. Why- Bad thermocouple. CM- Replaced fixed side thermocouple.0.0Medium
2026-08-21Die CastDie Cast 8Die Cast 8What: Trim press loading issue Why: Found wrong cutter on trim press, robot dragging against wrong cutter C/M: Replaced with proper cutter0.0Medium
2026-08-19Die CastDie Cast 5Die Cast 5WHAT: spray cartridge faults why: loosing sensor lights both top an bottom cylinder is bad think internal magnet broken c/m: replaced up/down spray cylinder0.0Medium
2026-08-19Die CastDie Cast 1Die Cast 1WHAT? Light out above turntables WHY Bad outlet CM replace outlet0.0Medium
2026-08-19Die CastDie Cast 6Die Cast 6WHAT? Robot will not HOME WHY? Stuck in program CM Function, Abort All, GO HOME prog. line 170, enter, SHIFT+FWD0.0Medium